79 research outputs found

    Transport of neutral IgG2 versus anionic IgG4 in PD : implications on the electrokinetic model

    Get PDF
    Background: It is debated whether transperitoneal membrane transport of larger (charged) molecules in peritoneal dialysis can be partially governed by the electrokinetic model. In this model, it is postulated that streaming potentials are generated across the capillary wall by forced filtration of an ionic solution, for example transcapillary ultrafiltration induced by osmotic forces as in peritoneal dialysis. We investigated the presence of streaming potentials in the process of transperitoneal transport in Peritoneal Dialysis (PD) patients by measuring ratios of dialysate concentrations of IgG2 (neutral) and IgG4 (negative), both 150kD, under different conditions of transcapillary ultrafiltration. Methods: Adult PD patients randomly got two consecutive dwells of 120 min each, with either 2 L Physioneal 1.36% or 3.86% glucose dialysis fluid (Baxter, USA) as their first dwell. A blood sample was taken at the test start, and dialysate samples were taken at 5, 15, 30, 60 and 120 min. IgG2 and IgG4 concentrations were measured (ELISA) and ratios calculated. Results: In 10 patients (65 +/- 17 years, 2017 months on dialysis), drained volume after 120 min was different between the 1.36% (1950 [1910; 2020] mL) and 3.86% (2540 [2380; 2800] mL) glucose dwells (P = 0.007). At none of the time points and irrespective of glucose concentration, a significant difference was found between the IgG2/IgG4 ratios at any time point. Conclusion: Our data failed to demonstrate a difference in the transport ratios of two macromolecules with same molecular weight but different charge, as would be expected by the electrokinetic model, and this despite sufficient differences in transcapillary ultrafiltration

    Cardiac Troponin Assessment Following Atrial Fibrillation Ablation: Implications for Chest Pain Evaluation

    Get PDF
    Background: The range of elevation of troponin I (tI) that is within expected limits from left atrial radiofrequency ablation for atrial fibrillation (AF) is not well described, though such information may be of clinical value. Objectives: Identify the expected range of tI values post-atrial fibrillation (AF) ablation. Methods: 31 patients undergoing AF ablation had a single tI level drawn the day following the procedure. Clinical variables were also collected, such as ablation type and radiofrequency (RF) time. Results: Paroxysmal AF was present in 23 patients, and 8 had chronic AF. The average RF time was 2627.8 ± 737.5 seconds. The mean RF power was 61.7 ± 4.3W (range 55-70W). The mean RF temperature limit was 53.6 ± 2.0°C (range 50-55°C). There was no clinical or electrocardiographic evidence of coronary ischemia in this population. The mean tI the following day was 3.21 ± 1.5 (range 1.48-8.41). There was no correlation between RF time, ablation type, ablation catheter size, and ablation temperature or ablation power and tI levels. Conclusions: Troponin I elevation post-ablation was ubiquitous. Knowledge of expected post-ablation tI levels may be helpful in the evaluation of post-procedure chest pain

    A Comparison of Atrial Fibrillation Monitoring Strategies After Cryptogenic Stroke (from the Cryptogenic Stroke and Underlying AF Trial)

    Get PDF
    Ischemic stroke cause remains undetermined in 30% of cases, leading to a diagnosis of cryptogenic stroke. Paroxysmal atrial fibrillation (AF) is a major cause of ischemic stroke but may go undetected with short periods of ECG monitoring. The Cryptogenic Stroke and Underlying Atrial Fibrillation trial (CRYSTAL AF) demonstrated that long-term electrocardiographic monitoring with insertable cardiac monitors (ICM) is superior to conventional follow-up in detecting AF in the population with cryptogenic stroke. We evaluated the sensitivity and negative predictive value (NPV) of various external monitoring techniques within a cryptogenic stroke cohort. Simulated intermittent monitoring strategies were compared to continuous rhythm monitoring in 168 ICM patients of the CRYSTAL AF trial. Short-term monitoring included a single 24-hour, 48-hour, and 7-day Holter and 21-day and 30-day event recorders. Periodic monitoring consisted of quarterly monitoring through 24-hour, 48-hour, and 7-day Holters and monthly 24-hour Holters. For a single monitoring period, the sensitivity for AF diagnosis was lowest with a 24-hour Holter (1.3%) and highest with a 30-day event recorder (22.8%). The NPV ranged from 82.3% to 85.6% for all single external monitoring strategies. Quarterly monitoring with 24-hour Holters had a sensitivity of 3.1%, whereas quarterly 7-day monitors increased the sensitivity to 20.8%. The NPVs for repetitive periodic monitoring strategies were similar at 82.6% to 85.3%. Long-term continuous monitoring was superior in detecting AF compared to all intermittent monitoring strategies evaluated (p <0.001). Long-term continuous electrocardiographic monitoring with ICMs is significantly more effective than any of the simulated intermittent monitoring strategies for identifying AF in patients with previous cryptogenic stroke

    Chronic kidney disease and arrhythmias: conclusions from a Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference.

    Get PDF
    Patients with chronic kidney disease (CKD) are predisposed to heart rhythm disorders, including atrial fibrillation (AF)/atrial flutter, supraventricular tachycardias, ventricular arrhythmias, and sudden cardiac death (SCD). While treatment options, including drug, device, and procedural therapies, are available, their use in the setting of CKD is complex and limited. Patients with CKD and end-stage kidney disease (ESKD) have historically been under-represented or excluded from randomized trials of arrhythmia treatment strategies,1 although this situation is changing.2 Cardiovascular society consensus documents have recently identified evidence gaps for treating patients with CKD and heart rhythm disorders [...

    2021 ISHNE/ HRS/ EHRA/ APHRS collaborative statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia Pacific Heart Rhythm Society.

    Get PDF
    This collaborative statement from the International Society for Holter and Noninvasive Electrocardiology/ Heart Rhythm Society/ European Heart Rhythm Association/ Asia Pacific Heart Rhythm Society describes the current status of mobile health ("mHealth") technologies in arrhythmia management. The range of digital medical tools and heart rhythm disorders that they may be applied to and clinical decisions that may be enabled are discussed. The facilitation of comorbidity and lifestyle management (increasingly recognized to play a role in heart rhythm disorders) and patient self-management are novel aspects of mHealth. The promises of predictive analytics but also operational challenges in embedding mHealth into routine clinical care are explored

    Shouldn’t Everyone Have an Implantable Cardioverter-Defibrillator?

    No full text

    Sudden Death Prevention With Implantable Devices

    No full text
    • …